Climate-Adaptive Design Strategies of Sports Stadia in a Hot Summer and Cold Winter Zone: A Case Study of Nanjing
Urban planning and design, with the objectives of energy efficiency and climate adaptation, is receiving more and more attention as urban energy consumption keeps rising. As technical representatives with large spans and high difficulties, sports stadia have a broad range of energy conservation and emission reduction compared with traditional buildings and have an extremely close relationship with the energy consumption of the building environment and urban microclimate, so it is necessary to study the climate adaptation design strategy of sports stadia. However, climate adaptive design has not given much thought to sports stadia nowadays. And the energy-saving strategies of sports stadia rely mostly on engineering expertise without taking into account the effect of sports stadia layout, shape, and structure on the urban microclimate. This paper investigates the energy-saving and climate-adaptive design techniques of sports stadia in the hot summer and cold winter zone of China using the layout of sports stadia as the research object. Firstly, we construct a climate adaptive design framework of sports stadia of “layout-shape-structure” based on the characteristics of sports stadia. Secondly, combined with typical examples of large-scale sports stadia in hot summers and cold winters, we establish an abstract model of architectural layout, shape, and structure based on climatic environment. In order to provide climate-adaptive design methods for sports stadia in hot summer and cold winter zones, the ventilation of the external and internal spaces of sports stadia is simulated, quantified, and compared using CFD software. The study’s findings suggest that the layout of sports stadia should take into account the direction of the local wind, that the goal of low energy consumption should guide the choice of building form, and that the internal wind and temperature environment should be stabilized during construction. The study’s findings can serve as a guide for comparable designs that aim to construct sports stadia with reduced carbon footprints. The Climate-Adaptive Design Strategies of Sports Stadia in a Hot Summer and Cold Winter Zone: A Case Study of Nanjing, China, will examine the impact of climate change on energy demand and design strategies. The study found that large-scale public buildings consume 2~4 times more energy than small-scale buildings in China, and 10~20 times more than residential buildings in Europe. China has set its own emission reduction targets of peaking carbon emissions by 2030 and achieving carbon neutrality by 2060, and the building sector is responsible for a sizeable portion of urban energy use. The report also found that climate change affects building energy consumption mainly through changes in heating and cooling demand, but this variation of climate changes varies in different regions. The two themes of the study include climate zoning, climate characteristics, and design responses. The third theme of research is mainly for research based on specific design spaces, and 28 technologies to consider low-energy technologies to reduce climate change.

Veröffentlicht : vor 2 Jahren durch Cheng, Kai, Jingjing, Chen, Dongxu, Xiong in Weather
The idea that climate change could have a significant impact on energy demand is generally acknowledged. China is currently the top emitter of greenhouse gases in the world as a result of its expanding energy consumption. At present, China actively participates in international efforts to reduce emissions and has set its own emission reduction targets of peaking carbon emissions by 2030 and achieving carbon neutrality by 2060 [ 1 ]. An important contributor to the nation’s economy, the building sector, is responsible for a sizeable portion of urban energy use. According to reports, 67% of the world’s energy needs comes from buildings [ 2 ]. Therefore, a significant stakeholder that may be successful in accomplishing this goal is the building industry. The issue of energy use and carbon emissions in public structures, particularly sizable public structures, is very apparent when looking at the construction business [ 3 ]. Previous studies have revealed that large-scale public buildings consume 2~4 times more energy than small-scale public buildings [ 4 ] and 10~20 times more energy than residential buildings in China [ 5 ]. Sports stadia, as typical large-scale public buildings, are typical representatives of large space and high performance in terms of building form, with unique volume and energy demand. For example, sports facilities consume about 8% of building energy in Europe [ 6 ]. In terms of the construction scale, according to China’s most recent Sixth National Stadium Census in 2013, there were 1.69 million sports facilities nationwide, with an area of 1.99 billion square meters [ 7 ]. In recent years, the “Healthy China 2030” plan has emphasized the need to improve people’s health by strengthening the construction of sports facilities [ 8 ]. It can be seen that under the impetus of the policy, the construction of sports stadia shows a rapid growth trend in the future. Therefore, there is an urgent need for the low-carbon development of sports stadia. Climate change affects building energy consumption mainly through changes in heating and cooling demand. However, the impacts of climate change vary in different regions. For example, in hot climates, the built environment is challenged by drought and overheating, whereas this challenge does not exist in cold coastal climates [ 9 ]. In China, the climate strip of the hot summer and cold winter zone is characterized by scorching heat in summer and severe cold in winter. At the same time, the large capacity of public space in sports stadia leads to a large heating and cooling demand. The above reasons cause the energy consumption of sports stadia in hot summer and cold winter areas to be large [ 10 ]. In response to this problem, the state has promulgated policies and regulations on energy conservation in residential buildings. However, policies and regulations on sports stadia for hot summer and cold winter areas are still lacking, which makes the study of sustainable design of sports buildings in this area a meaningful exploration. As global heating increases, all cities need to adapt to climate change. For the building industry, a range of measures are being taken to change building design and urban planning and to adapt existing buildings to climate change. In this process, climate-resilient design is emerging as an effective means of greening and low-carbon buildings. For example, Cerra (2016) proposed a framework for climate-resilient design applicable in non-coastal areas [ 11 ] and Liu et al. (2017) made recommendations for the climate-resilient design of new rural housing in their study area based on a literature review and field survey [ 12 ]. After a preliminary case study on the design of urban multi-family buildings at an early stage, Shen et al. (2020) proposed to incorporate future climate scenarios into the initial building design of two representative sites in Rome, Italy and Stockholm, Sweden [ 13 ]. Depending on the focus of the study, research on climate-resilient design can be broadly divided into three themes: (1) climate zoning, climate characteristics, and design responses [ 14 15 ]; (2) theoretical models for evaluating human thermal adaptation to spatial environments and thermal comfort [ 16 17 ]; (3) adaptation relationships between architectural spaces, urban spaces, and regional climates [ 18 19 ]. The first two themes focus on strengthening the climate adaptation of architectural spaces by analyzing the regional climate and meteorological conditions as well as the human physiological and psychological perception of the thermal environment and are mostly concerned with the determination and optimization of design principles and evaluation criteria. The third theme is mainly for the research of specific architectural spaces, generally based on specific cases such as design practice and actual engineering and around specific design methods and technologies. 28, In general, the design of climate-resilient buildings should consider building form and envelope [ 20 ]; climate and thermal comfort [ 21 ]; passive heating and cooling [ 22 ]; site planning [ 23 ]; windows, doors, and lighting [ 24 ]; natural ventilation [ 25 ]; adaptive low-energy technologies [ 26 ] to creatively answer the local climate and ecology through design. In the climate-adapted design process, corresponding design tools such as CFD (Computational Fluid Dynamics) simulation methods [ 27 29 ], Energy Plus [ 13 30 ], Radiance [ 31 32 ], Fluent 2016 software [ 33 34 ], and airflow network [ 35 36 ] can help to create a more climate-resilient building from the outset. Compared with residential buildings, there are fewer studies on the climate-adaptive design of public buildings at this stage. However, some scholars have paid attention to public buildings in recent years. For example, Qi and Wei (2020) proposed a climate-adaptive natural ventilation design adapted to the local climate and quantitatively evaluated the ventilation performance of the design using CFD [ 27 ]. Additionally, climate-adaptive design for public buildings is more often combined with green buildings. For example, Xu (2020) proposed a set of performance optimization design strategies for green public buildings adapted to the marine climate after analyzing the relationship between green public buildings and the external environment as well as the functional space design of coastal green public buildings [ 37 ]. Xue et al. (2016) explored the ventilation patterns of workplaces in order to optimize the passive climate-adaptive design strategies for green buildings in high-density tropical or subtropical cities on individual health perception; the results showed that the hybrid ventilation design could enable people to get in touch with nature [ 38 ]. Jing et al. (2021) proposed a cold-climate-adapted green public building design using the Chinese Pavilion of the 2019 World Horticultural Expo in Beijing, China as a research object [ 39 ]. Although more fruitful results have been accumulated on climate adaptation of public buildings, there are fewer studies on climate adaptation of buildings in hot summer and cold winter regions. At the same time, more studies have focused on office buildings and fewer studies have related to large-scale public buildings such as sports stadia. In addition, due to the lack of effective climate quantification tools and mature climate building strategies, a large number of architects rely on mechanical equipment when solving problems such as the difficulty of natural ventilation and lighting brought about by large spans, the difficulty of air intake demand brought about by large volumes, and the difficulty of coordinating the spatial arrangement of the grandstand and ventilation organization. They give less consideration to the impact of the layout of the sports stadia on the urban microclimate and the requirements of the energy saving of the built environment. Therefore, it is necessary to alleviate the problem of high energy consumption by strengthening the method of climate design. To fill the research gap, this study intends to give systematic and practical design solutions for a new construction and restoration of sports stadia, as well as to improve the sports stadia climate adaption to hot summer and cold winter zones. This study begins with three aspects of building layout, building form, and building structure and uses typical examples of large sports stadia in hot summer and cold winter zones as the basis for refining a set of representative standardized abstract models based on the three main objectives of climate environment, low energy demand, and climate control. The “simulation-quantification-comparison” method is then used to conduct a comparative analysis of the design measures for sports stadia in order to develop a set of recommendations for climate-resilient design strategies for sports stadia. This study investigated the climate-adaptive design of sports stadia in hot summer and cold winter regions. The findings of this research can help provide architects with unique perspectives on designing and evaluating sports stadia and serve as a reference for carrying out similar designs in order to promote the decarbonization of sports stadia.
2.1. Design Principles for the Climatic Adaptation of Buildings in Hot Summer and Cold Winter Zones Climate adaptive design is also known as climate design of buildings. In the stage of building scheme design, the climate environment of the area where the building is located is effectively and reliably analyzed; after considering the selection of appropriate climate adjustment measures, the design technology of better comfortable building space is achieved by using favorable climate factors and offsetting adverse climate factors [ 40 ]. From a climatic perspective, climate-responsive architecture not only responds to climatic factors through building site selection, community layout, building units, and architectural design details but also considers the impact of climatic factors on the indoor physical environment and comfort [ 41 42 ]. The climate conditions in China’s hot summer and cold -winter zone are harsh, with most areas experiencing sultry summers and high-temperature extremes, wet and cold winters, high annual precipitation, and high humidity in both winter and summer [ 43 ]. The extremes of climate create different thermal environmental needs in the region in winter and summer. In summer, there is a need to reduce the absorption of solar radiation, increase building shading, promote outdoor ventilation, and increase wind speed, which requires the provision of open spaces to guide ventilation and carry heat away from the building envelope; in winter, there is a need to increase the absorption of human solar radiation, reduce building shading, weaken outdoor ventilation, and reduce wind speed, which requires the provision of barriers to protect against wind and avoid the intrusion of cold winds into the building interior. Winter protection and warmth and summer ventilation and insulation are therefore key considerations in the design of buildings in the hot summer and cold winter zone [ 44 ]. This is also a contradiction in the design of buildings and climate adaptive design is the optimal solution to this contradiction. The advantage of this is that the design of buildings can be designed in such a way to shield the building from excessive solar radiation and to enhance natural ventilation, so that excess heat and humidity can be removed while blocking external heat intrusion as much as possible, indirectly affecting the temperature and humidity of the air and thus achieving better thermal comfort in the space. Therefore, according to the statements mentioned above, two principles of climate-adaptive design of sports stadia in hot summer and cold winter zones are proposed below: Climate adaptability is not passive, rather actively optimizes the microclimate environment of the building (which is conducive to energy saving) and attaches importance to and utilizes various climatic factors, such as the dominant wind direction, topography, landform, and other natural factors in summer and winter.
• None Balance the demand of buildings in different climates. The climate adaptability design of buildings in hot summer and cold winter areas can not only meet the needs of one side and ignore the needs of the other but is necessary to reasonably deal with the different needs of winter and summer. Carefully analyze the contradictory subjects and explore the best design method without affecting the basic needs of both parties, balance the thermal comfort of the two, and achieve the purpose of building energy conservation and climate adaptability. 2.2. Key Points for the Climatic Design of Sports Stadia in Hot Summer and Cold Winter Zones Sports stadia are buildings used for competition, teaching, entertainment, exercise, and other activities, with the characteristics of large investment, complex technology, large volume, and long service life. This research focuses on climate adaptation strategies in large spaces and complex structures, so the sports stadia in this research mainly consist of stadiums and various gymnasiums. Stadium refers to the building that can provide outdoor venues and provide users with certain seats for watching the games. Gymnasium refers to an indoor building that contains certain activity functions, commonly including swimming pools, basketball halls, badminton, etc. In the schematic design process of a gymnasium, the design process of “planning layout–shape design–structure modeling” is generally followed, so these points will be closely integrated in the climate adaptation design. The space of a sports stadia consists of two parts—the external space and the internal space—which are divided by the skin of the building. In terms of the areas of focus for the study of external and internal spaces, the focus of this study is on the public space for public use, as the aim of climate design is to provide a spatial environment with good thermal comfort for users. In this study, the external space is focused on the building layout and building shape. Numerous studies have shown that the external layout form of a sports center has an important impact on the wind environment of its external space [ 45 ]. Although the architectural layout of the sports center is rich and diverse, it can be briefly considered from the location relationship between the buildings and the final formation of the architectural layout of the sports center that is the result of several basic layout forms combined with adjusting the orientation of groups and individuals; the more common basic layout forms are the “one-line layout” and the “triangle layout”. The shape of a gymnasium is rich in variations and, from the examples of sports buildings, both planes and curved surfaces are used in the shape design. It is worth noting that, according to the authors’ practical experiences, it is found that the gymnasium has the physical characteristics of a very large external surface and the roof is the most important part for its heat exchange. Therefore, in the shape of the gymnasium, the roof form is most closely related to the thermal environment. Meanwhile, except for special structure stadia, the functions of stadia are generally more fixed; all are grandstands arranged around the internal center field and the shape is generally oval or nearly oval. Therefore, when analyzing the shape, this study does not consider the shape of the stadium. The structural form of sports stadia has the characteristics of large selectivity, deep influence, and strong acceptability, e.g., the canopy form, which, with greater selectivity, is taken as the research object. On the one hand, because the infield wind environment defined by the canopy is an important factor affecting the quality of on-site exercise and game use, on the other hand, because the canopy form has a more obvious and intuitive impact on the sports stadia structure, it is one of the exploration forms that unifies design form and physical properties. Therefore, the key points of climate adaptation design for sports stadia are shown in Figure 1 The unique massing and energy requirements of sports stadia lead to more pressing climate-resilient design needs than typical buildings. In general, starting from “planning layout–shape design–architectural modeling”, the design points of climate-adaptive design of sports stadia in hot summer and cold winter zones are proposed below. (1) In order to cope with the impact of climate factors on the regional environment of sports stadia, it is necessary to fully consider the particularity of regional climate, seek a reasonable layout mode of the sports stadia, and realize the unity of ventilation and wind protection. (2) In order to cope with the impact of climate factors on the outside of the gymnasium, it is necessary to seek a reasonable form to balance the wind and heat environment inside the gymnasium. (3) In order to cope with the disturbance of the wind environment inside the sports stadia caused by climate factors and combine the design requirements of architectural aesthetics, it is necessary to conduct reasonable discussions through reasonable structural design.
According to the standard of climatic regionalization for architecture, diverse climates are divided into five main zones in China, including the severe cold zone, cold zone, hot summer and cold winter zone, hot summer and warm winter zone, and temperate zone [ 46 ]. Among them, climate-adapted building design in the hot summer and cold winter zone faces the greatest conflicts and challenges because of the region’s hot and humid summers, cold and wet winters, high precipitation, high air humidity, and high average annual temperatures leading to a conflicting heat–light balance and a balance between insulation and openness throughout the year [ 47 ]. According to the statistics of the sixth national sports stadia survey, there are 1093 large-scale sports stadia in China, of which 300 are distributed in the hot summer and cold winter zone, accounting for 27.4% of the total number of sports stadia in the country, showing a clear trend of “dense in the east and sparse in the west” and “more in the south and fewer in the north” ( Figure 2 ). Therefore, the hot summer and cold winter zone is the most active region for sports stadia construction. As economic growth in the hot summer and cold winter zone increases, so do people’s expectations of thermal comfort and the energy consumption of sports stadia. Therefore, Nanjing (118.76 E, 32.04 N), a typical large city located in the hot summer and cold winter zone of China ( Figure 3 ), was chosen for the simulation study. Nanjing has abundant rainfall; annual temperature extremes range from a maximum of over 40 °C to a minimum of below 0 °C [ 48 ] and there is a clear wind shift between winter and summer, with northeasterly winds predominating in winter, easterly and southeasterly winds in summer, southeasterly and easterly winds in spring, and northeasterly winds in autumn, with some typhoon weather. With a number of major sporting events taking place, a range of sports stadia have been built throughout the hot summer and cold winter zone, including sports centers, stadiums, gymnasiums, and swimming pools, with a wide range of types, sizes, and functions. The existence of these buildings provides excellent conditions for the study of climate design. In this study, the following representative sports centers and stadiums that have hosted major events in the hot summer and cold winter zone of China were selected as prototypes for the abstract study: Nanjing Olympic Sports Center ( Figure 4 a), Wuhan Sports Center ( Figure 4 b), Shanghai Stadium ( Figure 4 c), and Hangzhou Olympic Sports Center ( Figure 4 d). The selected architectural examples are geographically located in Nanjing, Shanghai, Hangzhou, and Wuhan in the hot summer and cold winter zone. The stadia cover the classical shapes of sports stadiums and have strong typicality and orientation, which can comprehensively reflect the shape profile of sports stadia in the hot summer and cold winter zone. Quantitative research using abstract models of sports stadia can better circumvent some of the problems that exist in simulation research using architectural examples, such as the research object being too dissimilar in volume, the influencing elements being too complex, and the simulation parameters being too uncontrollable. The main focus of this study is on the coordination with the layout, shape, and the structure of the sports stadia. The abstract models of Nanjing Olympic Sports Center, Wuhan Sports Center, Shanghai Stadium, and Hangzhou Olympic Sports Center were used as the basis and a set of control models were generated by controlling the variables to be studied. For example, the layout is based on the same layout as the Wuhan Sports Center, while the building shape is extracted from the Shanghai Stadium and the building structure is generated from the Nanjing Olympic Sports Center. The specific abstract model is shown in Figure 5 The wind environment of the building layout and building form is simulated using Phoenics. In accordance with the boundary conditions set, quantitative wind data such as wind speed and wind direction are calculated for each location in the building space in the undisturbed steady state. Tecplot 2021 software is used to select points in the wind environment and measure the wind speed at a single point. The combination of Phoenics 2016 and Tecplot 2021 allows for more accurate measurement of the wind speed in the field under different conditions. Using Ecotect 2011 analysis, five parameters—heat transfer coefficient, access coefficient, solar absorption coefficient, decay time, and delay time—are set to simulate the thermal radiation conditions of each building form and to measure the radiant heat increment outside the building under different conditions. For the simulation of built environment spaces, the accurate setting of initial conditions is fundamental to the success of the simulation. Meteorological conditions are particularly important for the accuracy of the simulation results as they are an important initial condition. Although the building examples in this study are located in different parts of China’s hot summer and cold winter zone, the climatic conditions are generally very similar, despite slight differences. Also, the aim of this study is to investigate climate adaptation strategies for sports stadia in Nanjing. Therefore, all the simulations in this study choose uniform meteorological data as the initial condition setting, i.e., the meteorological data of Nanjing city is used to start the simulation study in order to facilitate a uniform standard cross-sectional comparison and to avoid errors arising from different meteorological parameters (as shown in Figure 6 ). In this paper, the weather tool is used to obtain the meteorological data of Nanjing and the data time is obtained as the average wind speed and sunshine radiation between 08:00 and 20:00 during the summer solstice in Nanjing in 2022.
Among the selected examples of sports stadia, the gymnasiums are rich in form, with a great variety of shapes, styles, and volumes. The richness of the architectural forms is derived from the basic plan forms. In the architectural examples, the planned form of the stadiums is predominantly oval and the planned form of the gymnasium is predominantly rectangular. Therefore, the shape of the stadium abstract model is regarded as an oval and that of the gymnasium abstract model is determined as a rectangle. According to the analysis of the actual case of the sports center, it can be found that the layout of the sports center is mostly in the form of a one-line layout and a triangle layout. Therefore, in the abstract simulation of the overall planning layout, the abstract model is constructed for these two categories. The dimensions of the oval stadium are 270 × 170 × 32 m with a height of 32 m, while the dimensions of the gymnasium are 180 × 100 × 25 m. As can be seen from the architectural examples, there are multiple ways of orienting the whole of both layout forms. In order to clarify the impact of the change in orientation of the general layout on the external environment, the simulation experiment chooses eight directions, including east, south, west, north, southeast, northeast, southwest, and northwest, as orientation variables for specific assignments. Among them, the direction of the square opening of the triangle layout is the orientation direction of the layout as a whole; the direction of the stadium of the one-line layout is the orientation direction. The final abstract model is shown in Figure 7 For the overall planning layout, the 3D heat flow CFD Phoenics 2016 software is used to simulate the outdoor airflow velocity, atmospheric pressure, and wind profile index in order to quantify the degree of impact of different layout strategies on the environment of the arena area. In the specific simulation process, typical climate data of Nanjing city throughout the year are selected as the atmospheric boundary conditions and wind speed data are set with an initial wind speed of 6.2 m/s and a wind direction of 45° (northeast). The model grid is set at 130 × 130 × 30, the simulation time is 120 s, and the time interval is 0.1 s. The simulation analysis of the planning layout and climate environment uses the wind speed distribution map and the wind speed data at the sampling point as the measurement parameters. The sampling points are located on the symmetry axis of the site layout and are named in order of orientation. In this simulation study, we first carry out 20 sampling points, 12 sampling points, and 8 sampling points for simulation calculation comparison. From the results point of view, the analysis results of the 12 sampling points are better, that is, the data are clearer and do not cost a lot of computing power, so the one-line layout is set with 12 sampling points and the triangle layout is set up with 12 sampling points. The data of the sampling point can better reflect the wind environment of the stadium surrounding the square space and can intuitively show the square wind environment of the stadium under different climatic conditions. The specific locations of the sampling points are shown in Figure 8 The Tecplot 2021 software is used to sample the wind speed at 12 points selected from the enclosed plaza of the sports center in a triangle layout and the data are summarized in Table 1 As can be observed from the wind speed and distribution maps of the sampling points in Table 1 , the average wind speed at each sampling point in the triangle layout of the square ranges from 1.8963 m/s to 4.7980 m/s, with an overall average value of 3.5594 m/s. The average wind speed in descending order of orientation is southwest > northeast > southeast > northwest > south > east > west > north. Under the wind speed condition of 6.2 m/s, wind environment simulations are carried out for eight different orientations of the triangle layout model, respectively, and the wind speed distribution is obtained (as shown in Figure 9 ). It is found that, when the axis of the triangular layout is southwest, the wind speed in the field is the largest, at about 4.7980 m/s. Followed by the northeast direction, the wind speed is about 4.6715 m/s. The wind speed in the north direction is the lowest, at only 1.8963 m/s. It can be said that, from the demand for ventilation in the field, the wind environment of the oblique layout is better than the positive layout and the wind blowing from the side of the square can make the square space obtain the maximum wind speed. When the axis of the field is north, the average wind speed of the field is the smallest; it is found that this is due to the air inlet and outlet being blocked by the stadium. Therefore, when choosing the overall orientation of the triangle layout, if ventilation is the main choice, priority can be given to the site axis parallel to the prevailing wind direction and the square space can be opened on the windward side, so that the external wind environment can pass through the site with less obstruction. Using tecplot 2021 software, 12 points are selected for wind speed sampling in the enclosed plaza of the sports center in the one-line layout; the data are summarized in Table 2 As can be observed in Table 2 , from the wind speed and distribution map of the sampling points, the average wind speed in the square with the one-line layout ranges from 2.0393 to 4.0338 m/s, with an overall average value of 3.1521 m/s; the average wind speed in descending order of orientation is east > west > north > south-east > south > south-west > north-east > north-west. As shown in Figure 10 , under the condition of a wind speed of 6.2 m/s, eight one-line layout models are simulated and calculated to obtain wind speed distribution diagrams. It can be found that, when the axis of the one-line layout is east-west, the wind speed of the site is up to 4.0338 m/s; after analysis, it is found that this is due to the wind direction crossing the site (the wind blows from the side of the site and the square space obtains a larger wind speed). At the same time, when the axis of the one-line is northeast and northwest, the axis of the sports stadia is parallel to the field and the wall of the gymnasium blocks most of the wind, so the wind speed of the site is minimal and the wind effect is significantly lower than that of other directions. Therefore, when choosing the orientation of the one-line layout, it is necessary to cross the site axis at 45° with the prevailing wind direction. The construction of sports stadia in the hot summer and cold winter zone is at a leading level and the construction of stadiums has also developed rapidly, with the completion of a number of gymnasiums such as the Nanjing Olympic Sports Center and the Hangzhou Olympic Sports Center. The design of these gymnasiums is innovative and the roof forms of the buildings are abundant. In order to systematically study nine types of roof interface forms of gymnasiums, such as flat roofs, four-pitch roofs, and gable roofs,; individual details are ignored (e.g., jagged simplified into corresponding sloping or curved surfaces, etc.). Then, based on the average dimensions of major gymnasium, a flat roof form of 65 × 40 × 22 m is used as the basic form and a set of abstract models of gymnasiums regarding the variation of roof forms is formed based on the unification of the nine types of gymnasiums in terms of internal volume, as shown in Figure 11 Ecotect 2011 analysis software is used to simulate the heat gain of building shapes in different roof forms. In the specific simulation process, the same Nanjing meteorological data is selected and a flat roof form of 65 × 40 × 22 m is used as the basic form, based on the nine types of gymnasiums being unified in terms of internal volume and unified in terms of the conditions of unshaded areas. The dome is taken as an example to calculate the heat increment of the external surface area. The amount of heat increment can better measure the relationship between solar radiation on the outer surface of the gymnasium ( Figure 12 ). For areas with hot summers and cold winters, the smaller the heat increment of the outer surface in summer, the lower the indoor temperature rises and the easier it is to maintain the indoor environment at a better level. As shown in Table 3 , after simulation and comparison of each form, it is found that there is an overall positive correlation between the area of the external surface form and the amount of solar radiation. According to the results revealed in Table 3 , we find that: (1) Compared with the other eight types, the heat increment of the outer interface of the dome (27,436,078.01 wh) obviously has the advantage of the lowest radiant heat increment, among which, compared with the short-sided concave type with the highest heat increment (136,742,413.30 wh), the radiant heat increment can even be reduced (79.93%), mainly because the dome is a spherical curved surface change and the heating surface area is smaller. The dome shape has the lowest radiant heat increment, so the dome has a significantly better radiant heat increment ability than other roof forms; it is widely used as the roof form of sports stadia. (2) Compared with the flat roof (53,983,330.70 wh), the radiant heat increment of a single slope roof (47,542,246.08 wh) increases (13.55%) and the radiation amount does not change significantly. (3) Compared with the average number of double slopes (74,511,081.39 wh), there is also a certain radiation reduction phenomenon (38.03%) in the flat roof form (53,983,330.70 wh), mainly because the double slope roof increases the roof surface area, which to a certain extent causes the increase of radiant heat increment. (4) The difference in radiation between the short-sided (73,880,238.81 wh) and the long-sided (75,141,923.97 wh) concave in the double slope form is not obvious. (5) The average heat increment of the concave roof is the highest and, after analysis, it is found that this is due to the fact that on the one hand, the concave part accumulates more energy and is not easy to volatilize and, on the other hand, the surface area of the concave building is the largest. Therefore, according to the amount of heat gained by the building shape, it can be sorted from largest to smallest: concave roof–sloped roof–flat roof–dome. The construction form of sports stadia takes a more microscopic approach to the external form and physical properties of the stadium, with the characteristics of being highly selective, influential, and acceptable. This study adopts the stadium canopy as a structural form because, on the one hand, the wind environment in the inner field defined by the stadium canopy is an important factor affecting the quality of exercise and competition use in the field and, on the other hand, because the canopy form has a more obvious and intuitive impact on the form of the stadium and is one of the forms explored to unify the design form and physical performance. Based on the previous case study, most of the stadiums are rounded flat and the impact of the canopy on the indoor wind environment is more direct. The permeability model of the canopy connection can be divided into three types: fully enclosed connection, semi-closed connection, and fully open connection, with the same floor plan using four-sided through canopy, with the size the same as the three models in the canopy profile form. Among them, the fully enclosed connection model is the gap between the canopy and the agent is completely shielded by the baffle. The semi-closed connection model is not set at the corner of the open connection model without occlusion. This study simulates the three forms and, from the results of the study, the internal wind environment has little relationship with the canopy connection form. In order to study readability, the semi-closed connection type is used here as an example to discuss the research results. This study uses the square inverted rounded building plan form in the site and the canopy profile form is divided into three kinds of upward tilt, flat and downward tilt, upward tilt canopy, and downward tilt canopy, respectively, on the basis of flat and straight canopy upward and downward tilt of 15°. The final abstract model is shown in Figure 13 where represents the wind speed at height , m/s; is initial wind speed (in this experiment, three wind speeds of 5 m/s, 10 m/s, and 15 m/s are taken); is height, m; represents reference height, taken as 10 m; is roughness coefficient, taken as 0.15. For the building construction analysis, three initial wind speed conditions are selected (5 m/s, 10 m/s, and 15 m/s) at a height of 10 m and urban gradient wind parameters are chosen for the air inlet. The specific expression for the gradient wind is as follows:whererepresents the wind speed at height, m/s;is initial wind speed (in this experiment, three wind speeds of 5 m/s, 10 m/s, and 15 m/s are taken);is height, m;represents reference height, taken as 10 m;is roughness coefficient, taken as 0.15. The model selected in this paper is an abstract model and the research content is the influence of canopy morphology on the infield wind environment. In the course of the study, each wind direction is simulated. The data results show little to do with the wind direction, considering that the composite variables would greatly increase the complexity of the study and weaken the accuracy of the single variable. Therefore, this paper ignores the influence of different wind directions and only discusses the influence of professional stadium canopy morphology on the infield wind environment from the perspective of an abstract model and selects a single wind direction as the initial condition. After simulation analysis, the following observations are noted under the same wind speed and direction in the external environment. (1) When the canopy is an upward canopy, a vortex is formed in the northeast and southwest areas, the average wind speed in the audience area on the west side is significantly higher than that in the east side, a small area of vortex circle appears locally on the northeast side, and the static wind area is actively small and has poor stability. (2) The average wind speed of the sports area is the smallest under the three canopy profile forms when the canopy is a flat canopy and there are many areas with sudden wind speed changes in the entire audience area, e.g., when the wind speed at the entrance is 15 m/s, the wind speed difference is about 7 m/s. (3) When the canopy is a downward canopy, the average wind speed in the field is large and a large area of low wind speed circle appears locally on the southeast side and the area of the quiet wind area is small. (4) In general, the whirlpool area in the field of the upward canopy and downward canopy is more obvious and less stable, especially in the sports area, and will have a certain impact on sports, while the flat canopy has the best stability and is the best for competitive sports. The wind speed difference between the inside and outside of the downward canopy is obvious and the speed reduction is the best. The speed reduction of the flat canopy is moderate and the area with sudden wind speed change in many places only appears in the audience area. The wind speed difference inside and outside the field of the upward canopy is not obvious and the speed reduction is poor ( Figure 14 ).
The unique wind and heat environment in the hot summer and cold winter zone has a great impact on sports stadia and the climate adaptation strategy of stadia is also more complicated. According to the simulation analysis above, climate adaptation strategies are proposed from three aspects: building layout, building shape, and building structure, as shown in Table 4 First of all, in the layout of the building, it is necessary to strengthen the air-induced air capacity of the sports stadia and balance the internal thermal environment of the gymnasium through ventilation and heat dissipation. After simulation studies, climate response can be summarized as follows: in the one-line layout, the axis is east-west and the wind speed of the site is the largest; when the axis is northeast and northwest, the wind speed of the site is the smallest and the induced wind effect is significantly lower than that of other directions. Therefore, under the demand of induced wind, the one-line layout is subject to wider changes in the ratio of external wind speed and site-affected area and whether the layout is reasonable or not has a greater impact on it. Through this simulation, the orientation of the one-line layout needs to cross the site axis with the prevailing wind direction at 45° to achieve the highest wind speed in the site. In the triangular layout, the southwest orientation has the largest wind speed in the field, followed by the northeast orientation, and the wind speed in the due north direction is the lowest. Regarding the need for ventilation, the wind environment of the oblique layout is better than the positive layout, that is, the wind blowing from the side of the square can make the square space obtain the maximum wind speed. At the same time, the square space needs to be made as little as possible on the windward side. Secondly, due to its large surface area and the most direct form of external contact, the roof of the gymnasium has huge radiant heat, which directly affects the thermal environment inside the gymnasium. Through simulation studies, it is found that there is a positive correlation between the external surface area of the roof and the amount of solar radiation as a whole. The dome is a spherical surface change, the heating surface area is smaller, and the dome has the lowest radiant heat increment, so the dome ability to reduce radiant heat increment is significantly better than that of other roof forms. The concave roof increases the external surface area of the building because the concave part increases; the concave part is easy to accumulate energy and is not easy to volatilize, resulting in the highest average radiant heat increment of such roofs. In the form of sloped roofs and flat roofs, the amount of radiant heat increment is directly related to its own shape system number and slope orientation. Therefore, according to the size of the heat gained by the roof shape of the building, it can be sorted from largest to smallest: concave roof–sloped roof–flat roof–dome. Therefore, the priority use of the dome can greatly reduce the radiant heat increment of the roof interface of the gymnasium and, in specific engineering practice, it should also be combined with subsequent measures such as reducing the building size coefficient, increasing external shading, and improving natural ventilation to effectively improve the thermal environment quality of indoor space. Finally, because of its semi-open form, the stadium has a direct connection between the internal environment and the external environment. The wind speed in the hot summer and cold winter zone is generally large; how to reduce the wind speed and stabilize the wind field in the field is one of the main concerns of stadia in this area. According to simulation results, it is found that the stability of the upward canopy and the downward canopy are poor, especially the whirlpool formed in the sports area, which will have a certain impact on sports, while the flat canopy has the best stability and is the best for competitive sports. The downward canopy has the best speed reduction. The flat canopy has moderate speed reduction and many areas with sudden wind speed change only appear in the audience area. The upward canopy has poor speed reduction, forming a vortex in the northeast and southwest areas. Therefore, compared with the upward canopy and the downward canopy, the flat canopy has more low wind speed areas and better wind resistance, which can effectively avoid the impact of windy weather on the training and competition of personnel in the stadium, improve the quality of use of the sports stadia, and improve the comfort of the overall environment.
This study uses Phoenics 2016, and Ecotect 2011 software as simulation tools and explores the general layout, building form, and canopy form of sports stadia in terms of wind and sunlight environment simulation, in response to the above-mentioned usage requirements and spatial characteristics. The findings of the study are summarized in a “simulation-quantification-comparison” approach and the rules and design strategies that are useful for climate design are summarized to propose a more comprehensive climate adaptation design strategy. According to the simulation results, when the triangular layout is made, the axis of the sports stadia is parallel to the dominant wind direction and the wind can better penetrate the square space formed by the two gymnasiums. In the one-line layout, due to the difference in layout, there is no enclosure space, so the wind speed is highest when the dominant wind direction runs diagonally through the site. For building shape, in the selection of roof form, it is better to choose the form with the smallest external surface area, such as a dome, because the external interface has the least contact and the external heat radiation also has the least interference with the indoor environment. When choosing the structure of the building, it is necessary to pay attention to the initial interference of the ground wind and choose a flat canopy with better wind resistance, more low wind speed areas, and better wind resistance, which will improve the comfort of the overall environment in the sports stadia. This study provides a reference and basis for the climatic design practice of sports stadia in hot summer and cold winter zones in a theoretical sense, thereby accelerating the pace of greening sports stadia. At the same time, at the practical level, the climate adaptation design strategies proposed in this paper provide a system of ideas and methods for contemporary sports stadia design with mutual perspectives and appropriate strategies, which enhance the green, healthy, and economic value of sports stadia. Although the results of the study are more instructive, there are still some shortcomings in this study. First of all, the simulation setting conditions in this study are relatively single, ignoring the influence of site greening, terrain, and other factors. At the same time, the abstract model of this study is also subject to the research methods, only considering the influence effect of the main aspects, and does not study the role of various details on the experimental results from the perspective of the fine model.